本文通过实验室水静压力试验系统模拟水密耐压电缆在水下的真实受压情况,主要研究3 MPa水静压力对300 m长水密耐压电缆体积变化的影响。结果表明:在3 MPa水静压力试验后电缆外观未发生明显变形,电缆与金属材料受力器连接处未发生开裂,电缆经水静压力试验后通电性能满足使用要求;水密耐压电缆的体积收缩变化率可以用压力传导液的液位变化率进行表征,电缆在3 MPa水压下保压1 h体积收缩变化率为6.4%。
This paper mainly studied the influence of watertight cable volume changing under 3 MPa water pressure by the laboratory water pressure test system. Result shows that cable shows no obvious deformation after pressure test, the connector between cable and metal material is unopened; The electrical signal can be transformed normally by the cable after the water pressure test; The volume change rate of watertight cable can be characterized by the variation of water level, the volume change rate of the watertight cable under 3 MPa water pressure is 6.4%.
2016,(s1): 90-92 收稿日期:2016-06-21
DOI:10.3404/j.issn.1672-7619.2016.S1.015
分类号:TM206
基金项目:海洋公益性行业科研专项经费项目(201105031-3)
作者简介:刘宁(1988-),男,国家海洋标准计量中心,硕士研究生,助理工程师,主要从事海洋仪器环境试验检测。
参考文献:
[1] 刘辉. 水密电缆用阻水材料的研究[D]. 上海:复旦大学, 2011.
[2] 舒杏娟. 纵向水密低噪音电缆的研制[J]. 光纤与电缆及其应用技术, 1987(1):16-19.
[3] 张强. 声纳用纵向水密电缆探讨[J]. 科技致富向导, 2011(15):270, 302.
[4] 刘国祥, 赵影, 吴洪明, 等. 声呐水密电缆:中国, CN201256011[P]. 2009-06-10.
[5] 韦玮, 戴显尧, 黄巍, 等. 一种电缆水密性测试装置及测试方法:中国, CN103364149A[P]. 2013-10-23.
[6] 李斌, 沙伟, 何志峰, 等. 具有纵向水密特性的舰船用深水电缆:中国, CN101299356[P]. 2008-11-05.
[7] 陈佶民, 刘旌平, 曾纪刚. 电缆纵向水密封性能检测技术研究[J]. 电线电缆, 2005(3):27-29.
[8] 舰艇电缆选择规则:CB/Z 221-1998[S]. 1999.
[9] 贺学明, 刘锋, 龚亚军, 等. 水密电缆与不锈钢接头的粘合性能[J]. 舰船科学技术, 2013, 35(2):126-128.
[10] 李永江, 陆云春. 舰船用纵向水密封电缆研究[J]. 船电技术, 2010, 30(12):32-36.
[11] 海洋仪器基本环境试验方法试验Q:水静压力试验:HY 016.15-1992[S]. 1986.