船舶海水管路的腐蚀影响管路运行的可靠性,严重时甚至会导致管壁破损,影响船舶的安全航行,研究管路的腐蚀程度检测技术具有重要意义。针对船舶海水管路布置紧密、管壁较薄、管径较小等特点,本文比较分析多种无损检测技术的原理及优缺点,重点分析脉冲涡流检测技术。针对信号检测器件,比较分析感应线圈、霍尔传感器以及多种磁电阻传感器的性能参数和研究现状,提出基于TMR阵列的脉冲涡流检测系统设计方案。
Corrosion of marine pipelines affects the reliability of pipeline operation, and even leads to pipe wall damage in serious cases, which affects the safe navigation of ships. Therefore, it is of great significance to study the detection technology of pipeline corrosion degree. In view of the characteristics of ship's seawater pipeline, such as compact layout, thin wall and small diameter, this paper compares and analyses the principles, advantages and disadvantages of various non-destructive testing technologies, focusing on pulsed eddy current testing technology. For the signal detection device, the performance parameters of the induction coil, the Hall sensor and various magnetoresistive sensors are compared and analyzed. The design scheme of pulse eddy current detection system based on TMR array is proposed.
2021,43(5): 88-91 收稿日期:2020-01-21
DOI:10.3404/j.issn.1672-7649.2021.05.018
分类号:U672.9
作者简介:张尧(1996-),男,硕士研究生,主要从事电磁无损检测技术研究
参考文献:
[1] 陈国均, 曾凡明. 现代舰船轮机工程[M]. 长沙: 国防科技大学出版社, 2001: 345−346.
[2] 张敏丽. 船舶海水管系腐蚀的原因及其防护[J]. 全面腐蚀控制, 2010, 24(6): 5-9.
ZHANG Min-li. Causes and protection of corrosion of marine seawater piping[J]. Total Corrosion Control, 2010, 24(6): 5–9.
[3] 沈玉娣. 现代无损检测技术[M]. 西安: 西安交通大学出版社, 2012: 2−3.
[4] 张小海. 射线检测[M]. 北京: 机械工业出版, 2013: 1−2.
[5] 郭伟. 超声检测[M]. 北京: 机械工业出版社, 2014: 2.
[6] 任吉林. 涡流检测[M]. 北京: 机械工业出版社, 2017: 2−3.
[7] 黄松岭. 现代漏磁无损检测[M]. 北京: 机械工业出版社, 2017: 2.
[8] 金信鸿. 渗透检测[M]. 北京: 机械工业出版社. 2014: 2.
[9] MICHNIAKOVA M, JANOUSEK L. The impact of various waveform shapes on the response signal in pulsed eddy current NDE[C]. ELEKTRO 2012, 2012: 439−442.
[10] LI J, WU X, ZHANG Q, et al. Pulsed eddy current testing of ferromagnetic specimen based on variable pulse width excitation[J]. NDT E Int., 2015, 69: 28–34
[11] 张辉, 杨宾峰, 王晓锋, 等. 脉冲涡流检测中参数影响的仿真分析与实验研究[J]. 空军工程大学学报, 2012, 13(1): 52–57
[12] 吴鑫, 谢基龙, 石坤, 等. 脉冲涡流参数对金属测厚影响的仿真分析[J]. 北京交通大学学报, 2012, 36(1): 122-131.
[13] HOSHIKAWA H, KOYAMA K. Eddy current distribution using parameters normalized by standard penetration depth[J]. Materials Evaluation, 1999, 9: 587–593
[14] FAVA J, RUCH M. Design, construction and characterization of ECT sensors with rectangular planar coils[J]. Insight, 2004, 46(5): 268–274
[15] HE Y, LUO F, PAN M, et al. Defect classification based on rectangular pulsed eddy current sensor in different directions[J]. Sensors and Actuators A: Physical, 2010, 157(1): 26–31
[16] 周德强, 闰向阳, 尤丽华, 等. 脉冲涡流矩形传感器参数的仿真优化与实验[J]. 传感器与微系统, 2013, 32(5): 13-16.
[17] ZHOU D, WANG J, HE Y, et al. Influence of metallic shields on pulsed eddy current sensor for ferromagnetic materials defect detection[J]. Sensors and Actuators A: Physical, 2016, 248: 162–172
[18] MAJIDNIA S, NILAVALAN R, RUDLIN J. Investigation of an encircling pulsed eddy current probe for corrosion detection[C]// IEEE Sensors 2014 Proceedings, Valencia, 2014: 835−838.
[19] LAI S, CHEN D, CHEN H, et al. Pulsed eddy current testing of inner wall flaws in pipe under insulation[J]. Procedia Eng., 2015, 130: 1658–1664
[20] XU Z, WU X, LI J, et al. Assessment of wall thinning in insulated ferromagnetic pipes using the time-to-peak of differential pulsed eddy-current testing signals[J]. NDT E Int., 2012, 51: 24–29
[21] PARK D G, ANGANI C S, KISHORE M B, et al. The effects of lift-off from wall thinning signal in pulsed eddy current testing[J]. Magn., 2012, 17(4): 298–301
[22] PARK D G, ANGANI C S, KIM G D, et al. Evaluation of pulsed eddy current response and detection of the thickness variation in the stainless steel[J]. IEEE Transactions on Magnetics, 2009, 45(10): 3893–3896
[23] TUMANSKI S. Induction coil sensors — a review[J]. Meas. Sci. Technol., 2007, 18(3): 31–46
[24] 王三胜, 郭强. 高温超导技术在微磁传感器中的应用与发展[J]. 物理, 2016, 45(03): 172-179.
[25] 刘迎春, 叶湘滨. 传感器原理、设计与应用[M]. 北京: 国防工业出版社, 2015: 231−232.
[26] 吉吾尔·吉里力, 拜山·沙德克. 隧道磁电阻效应的原理及应用[J]. 材料导报, 2009, 23(1): 338-340.
[27] CARDOSO F A, ROSADO L, FERREIRA R, et al. Magnetic tunnel junction based eddy current testing probe for detection of surface defects[J]. Journal of Applied Physics, 2014, 115(17): 516–520
[28] JIN Z, OOGANE M, FUJIWARA K, et al. Magnetic sensor based on serial magnetic tunnel junctions for highly sensitive detection of surface cracks[J]. Journal of Applied Physics, 2017: 122
[29] JIN Z, IHSAN M A, OOGANE M, et al. Serial magnetic tunnel junction based sensors for detecting far-side pits in metallic specimens[J]. Journal of Applied Physics, 2019: 58